China Long Life Centrifugal Slurry Pump Spare Parts of A05 and Rubber Material (F6083EP, E4145EP, F6147EP, DAM029HS1, C029HS1), Find details about China Casing, Impeller from Long Life Centrifugal Slurry Pump Spare Parts of A05 and Rubber Material (F6083EP, E4145EP, F6147EP, DAM029HS1, C029HS1) - Shijiazhuang Naipu Pump Co., Ltd.
|
LINERS | IMPELLERS | CASING | BASE | EXPELLER | EXPELLER RING | SHAFT SLEEVE | SEALS |
Standard | Chrome Alloy Natural Rubber |
Chrome Alloy Natural Rubber |
SG Iron | SG Iron | Chrome Alloy or SG Iron |
Chrome Alloy or SG Iron |
SG Iron | Rubber and Nitrile |
Options | Ferralium Hastelloy C 316 SS W151 Polyurethane Neoprene Butyl Viton Nitrile EPDM Hypalon |
Ferralium Hastelloy C 316 SS W151 Polyurethane Neoprene Butyl Nitrile Hypalon |
SG Iron Various grades |
MS Fabricated Cast Iron |
NI Resist Ferralium Hastelloy C Polyurethane 316 SS W151 |
NI Resist Ferralium Hastelloy C 316 SS Rubber W151 Polyurethane Neoprene Butyl Nitrile |
EN56C Ferralium Hastelloy C Titanium 316 SS 304 SS |
Ceramic Stellite Chrome Oxide Nordel Neoprene Viton |
Faults | Reason | Removal |
Pump fails to discharge any liquid. |
Air leaking into suction or gland Incorrect direction of pump rota- tion and impeller worn. Suction pipe blocked |
Sealed leakage. Check direction of rotation and replacing a new impeller. Removal lockage. |
Shaft Power consumption is excessive | Gland excessively tightened against packing rings. Rotating component is rubbing on a stationary part. Bearing worn. Drive belt tension too tight Flow rate too large Pump speed and ratio too high. Misalignment or unparallel of drive shaft and pump shaft. |
Loosen gland bolts. Removal the rubbed part. Replace the bearing Adjusting belt. Modifying the pump duty and speed. Adjusting drive and pump shaft. |
Bearing is over hearing | Lubricants too much or less. Containing impurities in the lubricant Bearing worn. |
Lubricating as requirements. Replace clean lubricant. Replace new bearing. |
Bearing has short life. | Misalignment or unparallel of drive and pump shaft. Shaft bent. Impeller unbalanced due to wear. Foreign object entered into the bearing or insufficient lubrication. Incorrect procedure followed in fitting bearings. |
Adjusting drive and pump shaft. Replacing shaft. Remove rubbing and replacing new impeller Clean the bearing. Replacing or refitting the bearings. |
Excessive leakage from stuffing box | Packing rings excessive worn. Shaft sleeve worn. Dirty sealing water. |
Replace new packing rings. Replace shaft sleeve. Change clean sealing water. |
Pump vibrates or is noisy. |
Bearings worn. Impeller unbalanced. Air entered into suction pipe or blocked. Flow rate is none-uniform and pump not primed. |
Replaced by new bearings. Replaced by new impeller. Discharge air and remove block. Improve on the pump feeding. |